Foot pedal operated valve for control of pneumatic devices. This is commonly used with pop-up stops and roller brakes.
OPERATION: For model VS2: Press foot pedal for pressure (pedal will stay in position). Press foot pedal again to exhaust pressure.
For model VS3: Press and hold foot pedal for pressure. Release foot pedal to exhaust pressure.
VALVE: Foot operated valve has 1/4″ NPT ports, 2-position, 4-way with detent pedal (model VS2, Part # PR0002179) or spring return pedal (model VS3, Part # PCP3897) . Pedal features a plastic foot guard. Metal foot guard also available.
FILTER, REGULATOR, LUBRICATOR (FRL): with 3/8″ ports. Includes fittings. Part #: PCP4616.
TUBING: Includes 20 Ft. of orange & 20 Ft. of blue 1/4″ polyurethane tubing.
AIR REQUIREMENTS: 80 PSI minimum pressure to 115 PSI maximum pressure.
NOTE: System pressure loss can occur over extended periods with no use. Not suitable for freezing temperatures.